Authors:

I Gede Putu Agus Suryawan, I Gusti Komang Dwijana

Abstract:

“In science of measurement, an error is defined as difference result of measurement and the real value of the measurand.Actually, this real value is never precisely identified; consequently, the error is unknowns as well. In this case, the error canonly be estimated without knowing its real quantity. If a value will be considered as an estimated error, this value should be taken as an uncertainty. Uncertainty of Vernier Calliper determined with Type A and Type B evaluation, then the combinedstandard uncertainty is determined. Vernier Calliper that calibrated with Gauge Block class 1, the maximum uncertainty is ± 3.27 µm in dimension of 12.7 mm, with 95% confidence level.”

Keywords

Keyword Not Available

Downloads:

Download data is not yet available.

References

References Not Available

PDF:

https://jurnal.harianregional.com/jem/full-2211

Published

2021-11-09

How To Cite

AGUS SURYAWAN, I Gede Putu; KOMANG DWIJANA, I Gusti. Analisis ketidakpastian pengukuran pada mistar ingsut rentang 0-30 cm.Jurnal Energi Dan Manufaktur, [S.l.], nov. 2012. ISSN 2541-5328. Available at: https://jurnal.harianregional.com/jem/id-2211. Date accessed: 28 Aug. 2025.